표 6. | Table 6. 3×3 송수신 무선전력전송 시스템에 대한 ADS 효율 시뮬레이션 결과 | ADS simulation results for 3×3 multiple-transceiver WPT system.
d/r | Stacked arrangement | Planar arrangement |
with CR | with Cfo | with CR | with Cfo |
PTE | PL(W) | PTE | PL(W) | PTE | PL(W) | PTE | PL(W) |
0.1 | 0.93 | 2722 | 0.88 | 50 | 0.93 | 1222 | 0.93 | 939 |
0.5 | 0.93 | 842 | 0.71 | 9 | 0.92 | 241 | 0.92 | 177 |
0.9 | 0.92 | 195 | 0.37 | 1 | 0.87 | 41 | 0.85 | 30 |
1.4 | 0.88 | 53 | 0.14 | 0.5 | 0.76 | 12 | 0.71 | 8 |
1.8 | 0.8 | 17 | 0.05 | 0.1 | 0.59 | 4 | 0.52 | 3 |
2.3 | 0.64 | 6 | 0.019 | 0.05 | 0.42 | 2 | 0.35 | 1 |
2.8 | 0.46 | 2 | 0.008 | 0.02 | 0.27 | 1 | 0.22 | 0.8 |
3.2 | 0.3 | 1 | 0.004 | 0.01 | 0.18 | 0.7 | 0.14 | 0.5 |