표 7. | Table 7. 20 GHz~100 GHz 삽입손실 측정의 불확도 총괄표 | Uncertainty budget of insertion loss 20 GHz to 100 GHz.

Uncertainty sources Value Distribution Division factor ui
dB dB
A type 0.007 Normal 1 0.007
Instrument Network analyzer S21 accuracy 0.089 Rectangular 3 0.051
Network analyzer power level linearity 0.090 Normal 2 0.045
Network analyzer frequency accuracy 0.000 Rectangular 3 0.000
Dynamic accuracy 0.100 Rectangular 3 0.058
Cable Tx cable amplitude stability 0.150 Rectangular 3 0.087
Rx cable amplitude stability 0.150 Rectangular 3 0.087
Mismatch Network analyzer - Tx cable 0.023 Rectangular 2 0.016
Tx cable - Tx Ant 0.076 U Type 2 0.054
Network analyzer – Tx Ant 0.002 U Type 2 0.001
Rx ant - Rx cable 0.045 U Type 2 0.032
Rx cable - Network analyzer 0.087 U Type 2 0.062
Rx Ant – Network analyzer 0.003 U Type 2 0.002
Antenna arrangement Antenna position (up and down) 0.135 Rectangular 3 0.078
Antenna position (left and right) 0.335 Rectangular 3 0.193
Antenna position (array) 0.065 Rectangular 3 0.038
Effects of phase position 0.382 Rectangular 3 0.221
Effects of site Reflect wave effect from wall, floor and ceiling 0.080 Rectangular 3 0.046
Fitting error Reactive range (more than about 50 % distance from source) 0.25 Rectangular 3 0.144
Fresnel range 0.48 Rectangular 3 0.277
Far field range 0.42 Rectangular 3 0.242
Combined standard uncertainty (reactive range), uc 0.384
Combined standard uncertainty (fresnel range), uc 0.451
Combined standard uncertainty (far field range), uc 0.430
Expanded standard uncertainty (The worst value), U (k=2) 0.902