표 2. | Table 2. 펄스 폭 및 RBW에 따른 UWB 펄스 신호의 첨두전력 비교 | A comparison of peak power for UWB pulse signal according to pulse width and RBW.
Oscilloscope measurement results | Spectrum analyzer measurement results | (2) Calculated Ppeak [dBm] | Error (1)−(2) |
Pulse width [ns] | ATT [dB] | Vpeak [V] | (1) Calculated Ppeak [dBm] | Measured Pavg [dBm] | Measured BW_10 dB [MHz] | RBW [MHz] |
2.44 | 0 | 0.120 | −8.42 | −45.38 | 920 | 3 | −6.70 | 1.71 |
−45.39 | 936 | 4 | −7.81 | 0.60 |
−44.35 | 928 | 5 | −7.82 | 0.60 |
3.16 | 0.127 | −7.92 | −42.97 | 632 | 3 | −7.56 | 0.37 |
−42.93 | 632 | 4 | −8.77 | 0.84 |
−41.64 | 632 | 5 | −8.44 | 0.52 |
4.0 | 0.128 | −7.86 | −42.39 | 536 | 3 | −8.41 | 0.55 |
−41.93 | 536 | 4 | −9.20 | 1.34 |
−40.86 | 536 | 5 | −9.10 | 1.24 |