표 6. | Table 6. Scale-down이 적용된 CIP1 mode에서의 제안된 모델과 측정간의 파라미터 비교 | Paraameter comparison of proposed equivalent model and measurement in CIP1 mode with applied scale down.
CIPI
Rise time (μ;s)
FWHM (ms)
Peak current (μ;A)
Source pulse requirements
<25
1.5±30 %
600±10 %
Proposed
25.3
1.5
599
Measured
26
1.47
593
Error (%)
−2.6
2
1