표 3. | Table 3. 디커플러의 PCI 인수시험 결과 | PCI acceptance tset result of decoupler.

Injection pulse
Contents Peak current(A) >2,500 Rise time ≤20 ns FWHM (pulse width) 500~550 ns
Simulated result 2,500 16.33 532.00
Measured result 2,550 19.67 512.94
Residual current
Contents Peak current (A) (<10 A) Peak rate of rise (A/s) <1×107 Root action (A√s) <1.6×10−1
Simulated result 7.23 16.87×103 11.88×10−3