표 5. | Table 5. 와셔 모터 실험과 모델링 시뮬레이션 비교 | Comparison of washer motor experiment and modeling simulation.

Parameter Experimental washer motor Simulation Experimental-simulation Error
Peak voltage [V] 42.4 41.1371 1.2629 −3.0 %
Rise time [ms] 7.40 7.189 0.211 −2.9 %
Pulse width [ms] 444.0 412.706 31.294 −7.0 %