Measurement standards for electromagnetic field strength (National notification) | | - Measurement method is not detailed. |
IEC 62110 | - Described averaged 3 points measurement method based on the body (0.5, 1.0, 1.5 m above the ground). | - A measurement point is 1 m of height away from the ground. It is applied for AC power systems. |
- 3 points averaged value is assessment of averaged exposure for the body. |
- Measure at 0.2 m away from surface of the DUT. |
IEC 62597 | - Described measurement method for electric railroad. | - Applied frequency up to 20 kHz. |
- Measure at 0.3 m away from surface of rolling stock in volume measurement. | - The value by 3 points measurement method considered height of power cable of the train(0.5, 1.5, 2.5 m) |
IEC61980-1 & IEC TC 106 WG9 TR | - Measuring inside the electric vehicle where the body is located | - It is the standards for wireless power transfer of electric vehicle. |