표 7. | Table 7. 국내외 기준에서 정한 전자기장 측정 방법의 장단점 비교 | Comparison of merits and demerits of EMF measurement method in domestic and international guidelines.

Standards Merit Demerit
Measurement standards for electromagnetic field strength (National notification) - Measurement method is not detailed.
IEC 62110 - Described averaged 3 points measurement method based on the body (0.5, 1.0, 1.5 m above the ground). - A measurement point is 1 m of height away from the ground. It is applied for AC power systems.
- 3 points averaged value is assessment of averaged exposure for the body.
- Measure at 0.2 m away from surface of the DUT.
IEC 62597 - Described measurement method for electric railroad. - Applied frequency up to 20 kHz.
- Measure at 0.3 m away from surface of rolling stock in volume measurement. - The value by 3 points measurement method considered height of power cable of the train(0.5, 1.5, 2.5 m)
IEC61980-1 & IEC TC 106 WG9 TR - Measuring inside the electric vehicle where the body is located - It is the standards for wireless power transfer of electric vehicle.