표 6. | Table 6. 철도의 전자기장 측정 위치 및 측정 방법 | EMF of the railroad measurement positions and measurement methods.

Measurement point Measurement method
Inside rolling stock Accessible areas for workers Surface - Measure at a minimum distance
- Measure on the floor surface above emission source at 0.5 m, 1.0 m, 1.5 m.
Volume - Measure at typical places where workers can be located.
- Measurement heights above the floor shall be 1.0 m, 1.5 m. The horizontal measuring distance to the walls is 0.3 m.
Public areas Surface - Same accessible areas for workers’ method.
Volume - Measure at places where public can be located.
- Measurement heights above the floor shall be 0.3 m, 1.0 m, 1.5 m. The horizontal measuring distance to the walls is 0.3 m.
Outside rolling stock Accessible areas for public and workers Surface - Measure at minimum distance and at an agreed number of measuring points.
Volume - Measure at distances of 0.3 m to the train surface taking into account the sources of emission of the rolling stock at 0.5 m. 1.5 m, 2.5 m height from the top of the running rails.