표 2. | Table 2. 직업인에 대한 전자기장 인체보호기준 | Reference levels of electric, magnetic and electromagnetic fields for occupational exposure.

Frequency ranges E-field [V/m] H-field [A/m] B-field [μT] Power density [W/m2]
1 Hz - 1.63×105 2×105
1~8 Hz 20,000 1.63×105/f2 2×105/f2
8~25 Hz 20,000 2×104/f 25×104/f
0.025~0.82 kHz 500/f 20/f 25/f
0.82~65 kHz 610 24.4 30.7
0.065~1 MHz 610 1.6/f 2.0/f
1~10 MHz 610/f 1.6/f 2.0/f
10~400 MHz 61 0.16 0.2 10
400~2,000 MHz 3f1/2 0.008f1/2 0.01f1/2 f/40
2~300 GHz 137 0.36 0.45 50