표 1. | Table 1. 일반인에 대한 전자기장인체보호기준 | Reference levels of electric, magnetic and electromagnetic fields for general public exposure.

Frequency ranges E-field [V/m] H-field [A/m] B-field [μT] Power density [W/m2]
1 Hz - 3.2×104 4×104
1~8 Hz 10,000 3.2×104/f2 4×104/f2
8~25 Hz 10,000 4,000/f 5,000/f
0.025~0.8 kHz 250/f 4/f 5/f
0.8~3 kHz 250/f 5 6.25
3~150 kHz 87 5 6.25
0.15~1 MHz 87 0.73/f 0.92/f
1~10 MHz 87/f1/2 0.73/f 0.92/f
10~400 MHz 28 0.073 0.092 2
400~2,000 MHz 1.375f1/2 0.0037f1/2 0.0046f1/2 f/200
2~300 GHz 61 0.16 0.20 10