Search

JKIEES, vol. 29, no. 12, pp.942-952, January, 2018
DOI. http://dx.doi.org/10.5515/KJKIEES.2018.29.12.942

EMF Measurement and Safety Assessment Method for Wireless Power Transfer System for Urban Railroad 도시철도용 무선 급집전 시스템 주변의 전자기장 측정 방법 및안전성 평가 방법 연구

김 윤 명․김 준 희*․주 영 준* Yoon-Myoung Gimm․Jun-Hee Kim*․Young-Jun Ju*
단국대학교 전자전기공학부(School of Electronics and Electrical Engineering, Dankook University) *(주)이엠에프세이프티 기업부설연구소(Research Laboratory, EMF Safety Inc.)

A wireless power transfer (WPT) system for an urban railroad is currently under development in S. Korea. This system supplies power to railroad cars using 60 kHz magnetic fields. The electromagnetic fields (EMFs) generated by the WPT system should satisfy established safety requirements for exposure of the human body to these fields. However, EMF measurements and the safety assessment methods for fields generated by the WPT system have not yet been established. As such, a measurement and safety assessment method for EMF generated by a WPT system for an urban railroad is proposed in this report. The EMF generated by this WPT system on a test railroad was measured and compared to the reference level set by the human safety standard for EMF exposure.

국내에서 개발되고 있는 도시철도용 무선 전달 공급 시스템은 60 kHz 자기장을 이용하여 객차에 전력을 공급한다. 무선 전력 전송 시 발생되는 전자기장에 인체가 노출될 때, 전자기장 세기는 인체 안전성 기준을 만족해야 한다. 하지만도시철도용 무선 급집전 시스템에서 발생하는 전자기장에 대한 측정 방법과 인체 안전성 평가 방법이 아직 확립되지않았다. 본 논문에서는 도시철도용 무선 급집전 시스템에서 발생되는 전자기장 측정 방법 및 인체 안전성 평가 방법을제안하였다. 제안된 측정 방법에 따라 무선 급집전 시스템 시험선로에서 발생되는 전자기장을 측정하고, 전자기장 인체보호기준치와 비교하였다.

Keyword : Wireless Power Transfer, EMF Safety Assessment, Urban Railroad, EMF Measurement

Download :